Automate and Power Your Business

UPS003705

UPS003705 - Meissner, MP210, 10KVA, 45-60mins, 400V/230V

The UPS003705 use a microprocessor controlled design using advanced high frequency pulse width modulated (PWM) techniques. The result is a compact, low component count UPS providing unequaled reliability and performance with very low noise levels. Our MP200 UPS range is packaged in a aesthetically pleasing cabinet with standard batteries housed within the UPS cabinet. A separate matching battery cabinet is available for extended run-times. The Meissner MP200 UPS is a true on-line design incorporating a static bypass switch as standard. In addition to this a manual make-break-switch is also provided for additional system reliability and ease of maintenance. The alarms and the on/off switch on the UPS is incorporated into the front facia of the unit. Standard protection is provided to reduce possible damage caused by lightning strikes. PLC Group supplies the entire range of MP200 UPS systems to the industry.

  • True double conversion on-line design
  • Available in single and three phase input
  • Maintenance Bypass Switch on all models
  • Static Bypass Switch as standard
  • High Frequency Pulse Width Modulated (PWM) microprocessor design
  • High overload capability
  • Very quiet operation (typically 55dBA and lower)
  • Compact, slimline cabinet on castors for easy installation
  • Simple Network Management
  • Protocol (SNMP) capability
  • Extended back-up options available
  • Solid, reliable on-line double conversion back-up for mission critical application
Model MP208 MP210 MP215 MP220 MP225 MP230
Input
Voltage 400V / 230V 400V
3 Phase or 1 Phase ±15% 3 Phase ±15%
Input Frequency* 50Hz or 60Hz ±15%
Charger d.c. Voltage Regulation ±1%
d.c. Ripple Voltage Less than 1%
Output
Rated Output 8kVA (6.4kW)  10kVA (8kW) 15kVA (10.5kW) 20kVA (14kW) 25kVA (17.5kW) 30kVA (21kW)
Power Factor  0.8PF lagging 0.7PF lagging
Load Power Factor Range From 0.6 IND to unity within kW rating
Rated Output Voltage ( I Phase) 230V
Regulation No Load to Full Load (Steady State) ±1%
Voltage Regulation with 100% Load Application ±5%
Recovery Time to Steady State 30 milliseconds
Overload Capability 110% for 30 seconds
Crest Factor Ratio (Peak / RMS Current) 3:1
Total Harmonic Distortion Less than 5% (typically 3% for linear loads)
Frequency – Free Running* 50Hz or 60Hz ±0.2%
Frequency – Synchronised with Mains* 50Hz or 60Hz ±2% (adjustable)
Static Transfer Switch
Transfer Time No Break
Overload Rating 100ms 1000%
General
Efficiency (Input to Output) 87%
Lightning Protection Designed to withstand standard test impulses of 6kV and 3kA
Environment
Acoustic Noise Level Typically 55dBA at 1 meter
Operating Temperature Range 0 – 40ºC
Relative Humidity (Non-Condensing) 95%
Battery
Blocks 16x12V blocks 22x12V blocks 32x12V blocks
Type – Internal Lead Acid Maintenance Free
Anticipated Life 3 to 5 years depending on number of discharges and temperatures
Standard Discharged Times (Mins)   10 (Other battery times or types available on request)
Dimension (mm) W x D x H
UPS Cabinet Only 440 x 750 x 1000
Battery Cabinet A 440 x 750 x 1000
Battery Cabinet B 585 x 750 x 1000
Weight (Kg)
UPS Cabinet 240 240 320 400 420 500
Battery Cabinet Typical 280
Interfaces
Standard Computer Interface. True intelligent RS-232
Optional Relay contacts and remote alarm panel with AS400 interface
Software Available on request / SNMP Capable
Note: The 8kVA and 10kVA units are also available in 110V input and 110V output