Galaxy 300 UPS

Galaxy 300 UPS

galaxy 300 ups largeGalaxy 300 UPS by APC

The APC Galaxy 300 UPS provides trusted and reliable power supply protection for small data centers, commercial buildings and technical facilities. The on-line double conversion topology supplies true isolation between input and output with a zero transfer time. Up to 30 minutes of integrated battery backup, internal mechanical bypass and parallel capability allows for higher levels of availability. Remote and local monitoring/management capability is achieved through a simple Web/SNMP interface and a user friendly display available in 14 languages.

Both three to three (3:3) and three to single (3:1) phase configurations are available for convenient power distribution. Serviceability is greatly enhanced by front panel access for ease of maintenance in confined spaces. All these features along with the included Start-Up and On-Site warranty service make the APC Galaxy 300 UPS the easiest UPS in its class to install, manage and maintain. PLC Technologies supplies the entire range of APC Galaxy 300 UPS systems to the Industry.

Models

Product Part Number Runtime (Hrs:Min)
10kVA 400V 3:1 with Transformer, Start-up 5×8 G3HTI10K3ILS 0:0
10kVA 400V 3:1 with Long Backup Charger, Start-up 5×8 G3HT10K3ILS 0:0
10kVA 400V 3:1 with 30min Battery, Start-up 5×8 G3HT10K3IB2S 0:0
10kVA 400V 3:1 with 10min Battery, Start-up 5×8 G3HT10K3IB1S 0:0
10kVA 400V 3:3 with Long Backup Charger, Start-up 5×8 G3HT10KHLS 0:0
10kVA 400V 3:3 with 10min Battery, Start-up 5×8 G3HT10KHB1S 0:0
10kVA 400V 3:3 with 30min Battery, Start-up 5×8 G3HT10KHB2S 0:0
10kVA 400V 3:3 with Transformer, Start-up 5×8 G3HTI10KHLS 0:0
15kVA 400V 3:3 with Transformer, Start-up 5×8 G3HTI15KHLS 0:0
15kVA 400V 3:1 with 10min Battery, Start-up 5×8 G3HT15K3IB1S 0:0
15kVA 400V 3:3 with 10min Battery, Start-up 5×8 G3HT15KHB1S 0:0
15kVA 400V 3:1 with Transformer, Start-up 5×8 G3HTI15K3ILS 0:0
15kVA 400V 3:3 with 30min Battery, Start-up 5×8 G3HT15KHB2S 0:0
15kVA 400V 3:1 with 30min Battery, Start-up 5×8 G3HT15K3IB2S 0:0
15kVA 400V 3:3 with Long Backup Charger, Start-up 5×8 G3HT15KHLS 0:0
15kVA 400V 3:1 with Long Backup Charger, Start-up 5×8 G3HT15K3ILS 0:0
20kVA 400V 3:3 with Transformer, Start-up 5×8 G3HTI20KHLS 0:0
20kVA 400V 3:3 with Long Backup Charger, Start-up 5×8 G3HT20KHLS 0:0
20kVA 400V 3:1 with Transformer, Start-up 5×8 G3HTI20K3ILS 0:0
20kVA 400V 3:1 with 25min Battery, Start-up 5×8 G3HT20K3IB2S 0:0
20kVA 400V 3:3 with 10min Battery, Start-up 5×8 G3HT20KHB1S 0:0
20kVA 400V 3:1 with Long Backup Charger, Start-up 5×8 G3HT20K3ILS 0:0
20kVA 400V 3:1 with 10min Battery, Start-up 5×8 G3HT20K3IB1S 0:0
20kVA 400V 3:3 with 25min Battery, Start-up 5×8 G3HT20KHB2S 0:0
30kVA 400V 3:1 with Long Backup Charger, Start-up 5×8 G3HT30K3ILS 0:0
30kVA 400V 3:3 with Transformer, Start-up 5×8 G3HTI30KHLS 0:0
30kVA 400V 3:3 with Long Backup Charger, Start-up 5×8 G3HT30KHLS 0:0
30kVA 400V 3:1 with 25min Battery, Start-up 5×8 G3HT30K3IB2S 0:0
30kVA 400V 3:3 with 10min Battery, Start-up 5×8 G3HT30KHB1S 0:0
30kVA 400V 3:3 with 25min Battery, Start-up 5×8 G3HT30KHB2S 0:0
30kVA 400V 3:1 with 10min Battery, Start-up 5×8 G3HT30K3IB1S 0:0
30kVA 400V 3:1 with Transformer, Start-up 5×8 G3HTI30K3ILS 0:0
40kVA 400V 3:3 with 10min Battery, Start-up 5×8 G3HT40KHB1S 0:0
40kVA 400V 3:3 with 20min Battery, Start-up 5×8 G3HT40KHB2S 0:0
40kVA 400V 3:3 with Long Backup Charger, Start-up 5×8 G3HT40KHLS 0:0
40kVA 400V 3:3 with Transformer, Start-up 5×8 G3HTI40KHLS 0:0
60kVA 400V 3:3 with 15min Battery (External Cabinet), Start-up 5×8 G3HT60KHB3S 0:0
60kVA 400V 3:3 with 30min Battery (External Cabinet), Start-up 5×8 G3HT60KHB4S 0:0
60kVA 400V 3:3 with 10min Battery, Start-up 5×8 G3HT60KHB2S 0:0
60kVA 400V 3:3 with 5min Battery, Start-up 5×8 G3HT60KHB1S 0:0
60kVA 400V 3:3, 0min Start-up 5×8 G3HT60KHLS 0:0
80kVA 400V 3:3 with 15min Battery (External Cabinet), Start-up 5×8 G3HT80KHB3S 0:0
80kVA 400V 3:3 with 10min Battery (External Cabinet), Start-up 5×8 G3HT80KHB2S 0:0
80kVA 400V 3:3 with 30min Battery (External Cabinet), Start-up 5×8 G3HT80KHB4S 0:0
80kVA 400V 3:3 with 5min Battery, Start-up 5×8 G3HT80KHB1S 0:0
80kVA 400V 3:3, 0min Start-up 5×8 G3HT80KHLS 0:0
UPS Battery Cabinet 5 G3HTBAT5 0:0
UPS Battery Cabinet 4 G3HTBAT4 0:0

Convenience

  • Easy to Install

Manageability

  • Integrated network management

Serviceability

  • Front-access servicing
  • 5×8 Start-up service included

Economy

  • Cost of acquisition

Availability

  • Wide input voltage range
  • Dual feed input
  • Double conversion on-line topology
  • Parallel-redundant capable

UPS Installation done by Professionals

PLC Technologies is at the forefront of supplying APC Galaxy 300 UPS installation services across the globe. Our work portfolio comprises installation and maintenance of uninterruptible power supplies across South Africa in the following areas, to name but a few: Production Plants, Industrial Factories, Banks, hospitals, financial institutions, data centres, prisons, hotels, residential and office buildings.

UPS Installation

UPS Maintenance services for complete piece of mind

PLC Technologies follow our own custom written APC Galaxy 300 UPS Maintenance procedures that includes more than 50 individual checks on various parts of the UPS and Batteries that either meets or exceeds the requirements for life-safety applications.

UPS Maintenance

Call for your FREE APC Galaxy 300 UPS quote

Don’t hesitate to get in touch with us should you require a FREE quote for APC Galaxy 300 UPS systems. Our friendly and highly trained sales team is ready to assist you and help you choose the perfect APC Galaxy 300 UPS.